Page 6 AXIS T81B22 DC 30W Midspan
Installation
1. Set the Power Selector to the correct setting (15/30W).
2. Connect the AXIS T81B22 to a DC limited power source (LPS, 12/24V
DC).
3. Connect the unit Data In jack (In) to your remote Ethernet network
switch using a shielded Ethernet cable.
4. Connect the Data & Power Out jack (Out) to your Axis splitter or
camera, using a shielded Ethernet cable.
Input
Camera/splitters
Data and
Data in
Port connectivity
indicator
DC Input connectivity
indicator
DIN Rail
12/24V DC
Power out
Power Selector (see table)
30W 15W