SINGLE INPUT: Both axis limit switches are connected to one pin.
Direction of travel determines if positive or negative switch is triggered.
LIMIT 1: Axis 1 negative and positive limit
LIMIT 2: Axis 2 negative and positive limit
LIMIT 3: Axis 3 negative and positive limit
LIMIT 4: Axis 4 negative and positive limit
LIMIT 5: Axis 5 negative and positive limit
LIMIT 6: Axis 6 negative and positive limit
LIMIT 7: Axis 7 negative and positive limit
LIMIT 8: Axis 8 negative and positive limit
SHIFT: Axis 9 negative and positive limit
GND: Ground connections
NOTE: If 'normally open' (NO) type switches are used, wiring must be done in parallel method, if
'normally closed' (NC) type switches are used, wiring must be done in serial method.
Software 'Invert' options allow use of ‘normally closed’ or ‘normally open’ switch hardware. This feature
can be set in File/Settings/Limit/Invert