7 of 9
8. Using the dropdown box, select “Image” as the group of parameters to modify. In the first
section, “Image”, check the box for “Trigger Data Enabled”:
9. Scroll down to the entry for each port (I0, I1, I2, etc.) and find the entry labeled “Ix Trigger Data”
(Where “x” is the specific port number) and place a check in the box labeled “Motion Level
Enabled”:
Note: The port numbering begins at 0 rather than 1. Thus, camera 1 is I0, Camera 2 is I1, etc.
10. Repeat step 10 for the other feeds for the 7014.
11. Close the browser and reboot the server every time any motion detection adjustments are
completed on the server to allow g! to reconnect and detect motion.
See the DVR Technical Note for information on setting up motion detection in the g! Software.