Do not operate the system under these condition or damage to the scanner may occur. See
section 3.2. "Input Power" for a more detailed discussion on this.
3.12. Mirror Alignment Mode
The mirror alignment mode shunt is
W5.
It allows the user to loosen the mirtor screws, align the
mirrors, and retighten the mirror screws, without the system going unstable. It does this by
lowering the loop gain of
the
system. When W5 is shorting pins 2 and 3, the system is in the
normal operating mode. When
the
jumper is between pins 1 and 2, the system will center itself
and feel somewhat
"limp"
compared to normal operation. The scanner will not follow any input
signals when in class
1
mode.
••Caution!! If
the
system is set up for class 0 operation, the scanners will still follow the input
signal, but at a much reduced loop gain. Do not operate the scanner in this mode except to align
the mirtors. Damage to the system could result and void the warranty. Refer to the tuning
procedure in section 6.0 for the mirror alignment procedure.