64 HyTechWorks©2013 – V3.1
bit 2 – Z capture trigger. “1” sets and “0” has no effect.
bit 3 – A capture trigger. “1” sets and “0” has no effect.
bit 31 – tool setting capture trigger. “1” sets and “0” has no effect.
hw_type – hardware type (see
HyCNC_GetHardwareInfo). 1 – original type; 2 – B/C
type.
The switch input is evaluated every millisecond. The movement should be no
more than 1 pulse per millisecond to achieve the best result when the trigger for
that moving axis is set.
This function is useful for homing or tool setting. The trigger is set during the
homing or tool setting stage, when the switch input changed, the coordinate is
captured. Then the coordinates are read back without any trigger setting. The
captured coordinate can be subtracted from the current coordinate to achieve
“zero” effect.