Axis 7100 Guia de Instalação Página 120

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 119
Modifying Access Levels
Advanced Dicing Technologies Ltd.
4.2-2
To Modify Access Rights to Parameters:
1 Double-click anywhere in the access rights columns of a grid row. The
existing access rights for the row appear in a multi-colored bar, as
follows:
2 Drag the sliders to change the access rights for each User type. For
example, drag the orange slider to the right to extend read only access
to the Users defined as Technicians.
3 Press Enter, or click outside the area of the multi-colored bar, to save
the modified access rights
- or -
Click Cancel to cancel the last change.
4 Click Save to save the modified access rights in the Recipe.
4.2.2 User Interface Elements
Access to the following functions in the Model 7100 software User Interface
can be restricted:
Adding and Deleting Parameters: Users with read-write access can
determine which Users can add or delete parameters by limiting access to
the Add and Delete buttons in the Parameters section of the
Programming Workspace.
1 Slider (blue)
2 Slider (orange)
Figure 4-10: Access Rights Bar
Figure 4-11: Extending Access Rights
12
Note: When modifying access rights, a lower Access Level cannot have
greater access rights than a higher Access Level. This means:
The Administrator cannot have less access rights than the Engineer,
Technician or Operator.
The User cannot deprive him or herself of rights. For example, an
Administrator cannot modify a parameter to be hidden or read-only for
other Administrators.