AXIS Camera Station Administration
38 AXIS Camera Station User’s Manual
Input/Output In the Input/Output field, choose if the alarm event is input or output
triggered.
• Inputs are used to create an alert or start/stop a camera.
See Example 1: Configure an alarm received from an INPUT on an AXIS
camera or video server, on page 40
• Outputs are controlled by the user and can be configured with texts on the
buttons controlling it. Outputs can control the output ports on selected
devices and activate e.g a siren or a light.
See Example 2: Configure an alarm received from an OUTPUT on an AXIS
camera or video server, on page 41
NO/NC Normally Open or Normally Closed. This determines how the device on the I/O is
configured. You can choose an open or closed I/O as the normal state:
• Normally Open means that the power streaming through the I/O is broken,
and there is no power pulse flowing through. An alarm can then be set up
to trigger when there is a constant power pulse, i.e. when the I/O closes.
• Normally Closed means that there is a constant power pulse flowing
through the I/O. An alarm can then be set up to trigger when the power
pulse flowing through the I/O is broken, i.e. when the I/O opens.
Flip-Flop Enabling Flip-Flop means that for outputs, the I/O will return to its normal
state after a few seconds.
Example: A gate is normally closed (NC). In this case, enabling Flip-flop means
that if the gate is opened the I/O device can be setup to automatically close the
gate after a few seconds.
I/O type-specific data Enter the IP address of the camera/video server the I/O is located on. Enter the
user/password for accessing the Axis device, if required. All Axis devices have a
default user called "root," which has the default password "pass".
On Alarm
PTZ position If the camera is PTZ-capable and uses preset positions, the position specified
here will automatically be assumed when an alarm occurs. If multiple PTZ
cameras are in use and all require positioning on an alarm, define a preset
position that uses the same name on each camera.
Alarm Priority Set the priority for the alarm here. Low priority means no email will be sent for
that alarm.
Enable sound on alarm This will play a sound every time there is an alarm. The sound file to play is
specified under the General tab, see General, on page 34.
Open Text The text that appears on the push button that opens the I/O.