Axis BTA 2100D Manual do Operador

Consulte online ou descarregue Manual do Operador para Software Axis BTA 2100D. Axis BTA 2100D Operator`s manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 597
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Varian, Inc.
2700 Mitchell Drive
Walnut Creek, CA 94598-1675/USA
©Varian, Inc. 2003-2009 Printed in U.S.A. 03-914979-00:5
Saturn® 2000 GC/MS
MS Workstation
Version 6
Operation Manual
NOTICE: Varian, Inc. was acquired by Agilent
Technologies in May 2010. This document is provided
as a courtesy but is no longer kept current and thus
will contain historical references to Varian. For more
information, go to www.agilent.com/chem.
Vista de página 0
1 2 3 4 5 6 ... 596 597

Resumo do Conteúdo

Página 1 - Operation Manual

Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA ©Varian, Inc. 2003-2009 Printed in U.S.A. 03-914979-00:5 Saturn® 2000 GC/MS MS Wo

Página 2

8 Batch Report Printing without Recalculating ...

Página 3 - Contents

98 temperatures and this is okay. In general use the lowest temperature which provides acceptable chromatography. The manifold bakeout functions c

Página 4

99 3800 GC System Control Window The Instrument Window Once you have configured your 3800 GC in an instrument, you may view the Instrument Window.

Página 5

100 Elements of System Control Toolbar System Control Toolbar provides you with buttons to do the most common tasks performed in System Control. M

Página 6

101 Multiple detectors can be viewed horizontally or vertically. The component status display can be changed to view detailed status of each comp

Página 7

102 Installed hardware is listed here. The setup is changed from the 3800 GC front panel. The 3800 Setup dialog for the Saturn 2000R/3800 is al

Página 8

103 Show only the chromatogram display. Continue to view the signal after the run Select the detector(s) to view. Hide/unhide the Toolbar. Set

Página 9

104 Adjust zero offset. Adjust amplitude scale. Adjust time scale. Hide/unhide vertical amplitude scale slider. Documenting Module Information Yo

Página 10

105 You may add and edit sections and items in sections. The injections value is updated each time an injection is performed. Select Help for det

Página 12

107 3800 GC Injecting a Single Sample Overview By now you should have your 3800 GC configured and a basic Method built for data acquisition. If th

Página 13 - Getting Started

9 File Revision Settings ...

Página 14

108 the Inject Single Sample, double-click on the vial position you wish to inject from in the carrousel display. This will bring up the Inject Si

Página 15 - MS Workstation Toolbar

109 Specifying Per-Sample Data Handling Parameters Most Data Handling parameters are specified in the Method used during the injection. Some param

Página 16 - Button

110 Specifying a RecalcList You can choose to create a new RecalcList, append to an existing RecalcList, or not create nor update a RecalcList. To

Página 17 - Application Buttons

111 List of Data Files generated in System Control, and a Quick Link button above provides access to the selected file. Automation actions and err

Página 18 - Quick Link Buttons

112 Choose the instrument for the injection. Enter information about the sample. Enter the name of the Method you wish to use. Enter the name of

Página 19

113 3800 GC Injecting Multiple Samples Introduction By now you should have your 3800 GC configured and a basic Method built for data acquisition.

Página 20

114 Spreadsheet columns can be sized by dragging their border using the left mouse button. Right click on the column headers for formatting optio

Página 21

115 For sequentially numbered Sample names, enter the starting number and the number of entries to add to the SampleList. The Sample Names will ha

Página 22

116 makes it easy to see how a Data File created with this filename specifications would appear. Specifying Per-Sample Data Handling Parameters Mo

Página 23

117 If you choose to create a new RecalcList, this automatically generated RecalcList will not overwrite an existing RecalcList. If a RecalcList

Página 25 - Small Buttons on Toolbar

118 Click on the Carrousel button. The Carrousel dialog box is displayed. Click on the button to perform the desired operation. The SampleList is

Página 26

119 List of Data Files generated in System Control, and a Quick Link button above to access the selected file. Automation actions and errors are l

Página 27 - 2000 MS Module Control

120 Select Activate Method from the Sample Type cell. Click on the AutoLink button. The Activate Method dialog box is displayed. Enter the name

Página 28

121 The Sequence window for the open Sequence is displayed. Enter the Method and SampleList to use. You may enter any number of Sequence lines. C

Página 30 - Network

123 3900 GC System Control Window The Instrument Window Once you have configured your 3900 GC in an instrument, you may view the Instrument Window

Página 31

124 Elements of System Control Toolbar System Control Toolbar provides you with buttons to do the most common tasks performed in System Control. M

Página 32

125 Multiple detectors can be viewed horizontally or vertically. The component status display can be changed to view detailed status of each comp

Página 33

126 Installed hardware is listed here. The setup is changed from the 3900 GC front panel. The 3900 Setup dialog for the Saturn 2000R/3900 is al

Página 34 - Company Network)

127 Show only the chromatogram display. Continue to view the signal after the run Select the detector(s) to view. Hide/unhide the Toolbar. Set

Página 35 - Click Setup

11 Getting Started About this Manual/Help This manual/help system contains information about how to acquire data, build methods, and operate the S

Página 36

128 Adjust zero offset. Adjust amplitude scale. Adjust time scale. Hide/unhide vertical amplitude scale slider. Documenting Module Information Y

Página 37

129 Select Edit Module Info. The Module Information Editor window is displayed. You may add and edit sections and items in sections. The injectio

Página 39

131 3900 GC Injecting a Single Sample Overview By now you should have your 3900 GC configured and a basic Method built for data acquisition. If th

Página 40

132 Specifying the Data File Name and Path Data File names can be up to 255 characters long. Sample ID, injection date, module name, and injection

Página 41

133 Specifying a RecalcList You can choose to create a new RecalcList, append to an existing RecalcList, or not create nor update a RecalcList. To

Página 42

134 The total number of injections completed is shown in the Instrument Status window. Automation actions and errors are logged in the Message Log

Página 43

135 Choose the instrument for the injection. Enter information about the sample. Enter the name of the Method you wish to use. Enter the name of

Página 45

137 3900 GC Injecting Multiple Samples Introduction By now you should have your 3900 GC configured and a basic Method built for data acquisition.

Página 47

138 Spreadsheet columns can be sized by dragging their border using the left mouse button. Right click on the column headers for formatting optio

Página 48

139 When you press the Begin button, you are prompted for the Method to use. Enter the Method to use for the run……or browse for the Method file.

Página 49 - 2000 MS Instrument Control

140 The right side of this dialog box allows you to create a filename “specification”. You can combine text entry with the “%” variable symbols sh

Página 50 - 2000 Module Window

141 Changing Default SampleList Entries When you add a new row into a SampleList, default values are used for each cell. To change the default val

Página 51 - Manual Control

142 All Message Log entries are stamped with the time they occurred. Saving SampleLists for Later Use When you make changes to the open SampleLis

Página 52 - Adjustments tab

143 Enter the name of the Method to use……or pick the Method from a list of files. When this line is encountered during automated injections, the

Página 53 - Auto Tune

144 Enter the Method and SampleList to use. You may enter any number of Sequence lines. Choose the action to be done in that step of the Sequence

Página 54 - Set Points

145 System Control Menus File Menu Menu Item Description Activate Method… Displays the Activate a System Control Method File dialog box to acti

Página 55 - Diagnostics Mode

146 Menu Item Description Remember Last Open Files When checked, upon startup System Control will restore the active Method and any automation fi

Página 56 - System Test

147 Inject Menu Menu Item Description Inject Single Sample... Opens the appropriate Inject Single Sample Dialog Box for your system. Used to inj

Página 57 - Monitor Window

13 MS Workstation Toolbar Overview Saturn GC/MS Workstation is a suite of applications for controlling chromatographs, collecting data from chro

Página 58 - Shutdown Mode

148 Menu Item Description Reset Modules Stops the current run, resets all modules simultaneously. Automation proceeds to the next injection afte

Página 59 - Acquisition Mode

149 Menu Item Description #:instrument name Displays the Instrument Status window and Status and Control windows for the named Instrument. i.e.

Página 60

150 Menu Item Description Arrange Icons Arranges the icons, if any, in a row at the bottom of the System Control window. Sequence:, SampleList:

Página 61 - 2000 MS Instrument Window

151 System Control Toolbar Main Toolbar The System Control main toolbar appears at the top of the Configuration and Instrument Windows. Item Des

Página 62

152 Resume automation after a pause. Automation will continue at the point that it was suspended. Stop automation. Stops the current run, resets

Página 63

153 2000 MS Method Basic Scan Functions Introduction The Saturn GC/MS analyzes the gas-phase ions formed from a sample in terms of their mass-to-c

Página 64 - Inject Single Sample Menu

154 frequency and amplitude is also applied to the endcap electrodes during the analysis to improve ion injection and unit mass resolution. The Sa

Página 65

155 2000 MS Method Chemical Ionization Introduction Chemical ionization (CI) provides mass spectral data that complement electron ionization (EI)

Página 66

156 The figure below shows the scan function for chemical ionization. A Reagent gas ionization, time determined by the previous scan B Ejectio

Página 67

157 4. Reagent gas ions are ejected. (D) 5. The CI mass spectrum is acquired for the sample ions. (E) SECI ejects all ions above a cutoff mass b

Página 68

14 Elements of the MS Workstation Toolbar Application Buttons for immediate access to the selected application. Tooltip shows the application nam

Página 69

158 NOTE: Reagent ion formation can be a complex process. For example, for proton transfer CI with methane used as the reagent gas, reagent gas

Página 70

159 period. The CI storage Level is typically set to a value that is lower than the mass of the reagent ion of interest. The CI Storage Level c

Página 71 - Saturn Module Keypad Dialog

160 Prescan Ionization Time Prescan Ionization Time parameter as used in MS/MS applications is set to 200 sec. Default Parameters for Reagent Ga

Página 72 - Spectrum Toolbar

161 CI Background Mass Set Too Low. CI Background Mass Properly Set. How to Determine the Proper Ejection Amplitude The proper setting for the R

Página 73

162 Chemical Ionization Using Fixed Parameters The reaction parameters that are normally set by the Auto Control can also be set manually. For C

Página 74

163 Choice of Liquid CI Reagents Many liquids may be used as CI reagents. The general requirements are a moderate vapor pressure and fairly low mo

Página 75 - Status and Control Window

164 Setting the Reagent Pressure for Liquid CI Reagents Connect a liquid reagent reservoir containing the chosen liquid to the liquid reagent inl

Página 76

165 Adjusting the CI Reagent Gas Pressure for Gases Other Than Methane When you install a new supply of reagent gas, you must adjust the pressure

Página 77 - SetPoints

166 Reagent Ion Spectrum for Ammonia Tuning for CI Operation In CI, as in EI, the Saturn GC/MS is tuned to achieve the best combination of maximu

Página 78 - Adjustments

167 The practical advantages of low-pressure CI are:  No need for an expensive vacuum pumping system to handle the large amounts of reagent gas

Página 79

15 Application Buttons Used to monitor instrument status, perform automated injections, and perform batch recalculations. Used to view and edit

Página 81 - See the Chemical Ionization

169 2000 MS Method Command Reference Spreadsheet editing Item Description Add Duplicates MS parameters of the last segment and adds it to the e

Página 82 - Autotune Mode

170 Item Description Segment Description Comment Line. 20 characters can be entered. Start Time Start time of segment in minutes. 0.00 to 649.99

Página 83 - Method and Set Points

171 Ionization Mode Item Description EI-Fixed Ions formed by electrons for a time set in method. EI-Auto Ions formed by electrons for time calc

Página 84

172 Segment Setpoints Item Description Scan Time The duration of each scan (in seconds). Values from 0.10 to 5.00 seconds per scan. Below is disp

Página 85 - Air/Water Check

173 Ionization Mode - EI Auto Item Description Mass Range Segment Breaks The EI scan is made up of between 1 and 6 scan segments, each holding

Página 86 - Electron Multiplier Tune

174 Ionization Mode - EI Fixed Item Description Mass Range Segment Breaks The EI scan is made up of between 1 and 6 scan segments, each holding

Página 87

175 The CI Parameters CI Auto Reagent Gas Item Description Reagent Gas Select CI reagent for application. Select User-Defined for gas not list

Página 88 - Mass Calibration

176 Item Description Maximum reaction time Maximum time that reagent gas ions are allowed to react with sample molecules to form ions. The maximu

Página 89 - Trap Function Calibration

177 Ion Storage (SIS) Parameters Item Description Storage Mass Ranges Table to enter ion(s) or range of ions for selective storage. Enter up to

Página 90 - Temperatures Mode

16 Quick Link Buttons Most Recently Used Data File. A menu of operations that can be performed on the Most Recently Used Data File are displayed

Página 91

178 The MS/MS Ion Prep Method Item Description Isolation Mass to be isolated and window of isolation Parent Ion Mass (m/z) Integer or exac

Página 92

179 Item Description MS q Calculator Use the q Calculator for suggested excitation storage levels. Desired Product Mass Enter product mass expe

Página 93

180 Item Description Isolation Time The dwell time during which the rf field is held constant in the high mass ejection step. Range 1 - 10 msec.

Página 94 - Diffusion Pump Shutdown

181 Item Description Isolation Time The dwell time during which the rf field is held constant in the high mass ejection step. Range 1 - 10 msec.

Página 95 - Diffusion Pump Startup

182 Item Description Excitation Storage Level Rf storage level in m/z when the dissociation waveform is applied following isolation. The excitatio

Página 96 - Acquisition

183 Item Description High Edge Amplitude Amplitude of broadband waveform used to eject masses above the isolated parent ion. Default is 30 volts.

Página 97

184 Excitation Storage Level Rf storage level in m/z when the dissociation waveform is applied following isolation. The excitation storage level

Página 98 - Electron Multiplier Gain

185 MSn MSn uses two parent ions for sequential dissociation. The additional dissociation step can be used to increase selectivity of analyte ver

Página 99 - Ion Trap Temperature

186 Item Description Waveform Type Nonresonant or resonant excitation. Excitation Storage Level Rf storage level in m/z when the dissociation w

Página 100 - AGC Target TIC Value

187 Item Description Excitation Time Time for collision-induced dissociation (CID) by ion excitation. Range 0 to 1000 msec. The default is 20 mse

Página 101 - The Instrument Window

17 MS Workstation Toolbar Options Right-click the bar to display the Toolbar Options. A menu of MS Workstation Toolbar configuration options and

Página 103

189 2000 MS Method Electron Ionization The Electron Ionization Scan Function with Automatic Gain Control (AGC) The ion trap has a maximum storage

Página 104

190 GC peaks) the maximum ionization time of 65 milliseconds is selected, which offers maximum sensitivity. As the amount of analyte increases, th

Página 105

191 The ion current measured during the AGC prescan is known as the AGC peak area. The AGC peak area is proportional to the number of ions formed

Página 106

192 mass range and scan time, more than one microscan may be obtained during each scan. (The number of microscans per scan for each set of mass-ra

Página 107

193 Software Parameters Segment Setpoints Scan Time The duration of each scan (in seconds). The scan time can be set to any value from 0.100 to 5

Página 108

194 Mass Defect Mass defect is defined as the difference between the nominal mass of an atom (or ion) and its exact mass. Its importance arises f

Página 109 - Overview

195 Mass Range Segment Breaks Each EI scan is divided by default into four mass segments: 10 to 99 m/z, 100 to 249 m/z, 250 to 399 m/z and 400 to

Página 110

196 Maximum Ionization Time This sets the limit for the longest ionization time which AGC can use. For maximum sensitivity, start with the defaul

Página 111

197 Ionization Mode - EI Fixed When AGC is off, a fixed ionization time scan function is used to coordinate the processes that occur in the ion tr

Página 115 - Samples

199 2000 MS Method Ion Preparation The Ion Preparation Method The two fundamental processes in mass spectrometry are ion creation and ion analysis

Página 116

200 either or both segments of the scan function. Chemical ionization uses the previous scan for ion control. As shown below, the analytical scan

Página 117

201 Specifying the Ion Preparation Parameters The Ion Preparation Parameters control how the basic EI or CI scan functions are modified to prepa

Página 118

202 Initially, you specify the mass window of ions to be stored. Because each mass has a unique secular frequency at a given storage rf voltage, i

Página 119

203 Under Storage Mass Ranges, enter the low m/z integer mass and the high m/z integer mass for each of the mass windows to be selectively stored

Página 120

204 As shown below, the window of ions ejected also depends on mass. A single mass can only be ejected at low mass values. If a single high mass

Página 121

205 Tips for Using SIS Observe these recommendations for best results when using the SIS application.  When selectively storing ions that are ea

Página 123

207 2000 MS Method MS/MS Option: Theory of Operation Overview This section describes the four basic operations in Saturn Ion Trap Tandem Mass Spe

Página 124

19 Launching Applications from the MS Workstation Toolbar Using the Application Icon Buttons Saturn GC/MS Workstation applications appear as icon

Página 125

208 MS/MS Scan Function Parent Ion Isolation The parent ions can be completely isolated from any remaining matrix ions in another two-step proces

Página 126

209 (parent ion) m/z. The m/z distribution that results from the CID process depends on the characteristics of the parent ion and the amount of en

Página 127

210 multiple chemical bonds or that undergo significant rearrangements. Periodic modulation through ion resonance results in an averaging of the e

Página 128

211 Note that at a storage level of 48 m/z and a CID bandwidth of 4 kHz, the mass range increases from 3 to 40 m/z when the parent ion mass increa

Página 129

212 level of parent or product ions in the analytical scan results in consistent, reproducible product ion spectra. Lower target values may be req

Página 130 - Adjust time scale

213 Under the Isolation header, enter the Isolation Window (m/z). The full mass isolation window range is 1.0 to 14.0 m/z; the actual range is mas

Página 131 - Select Edit Module Info

214 NOTE: If the excitation amplitude used is too large, the parent ion and product ion spectra will be absent because both ions will be ejected

Página 132

215 Customize Parameters window is separated into three sections. Ionization, Isolation and Dissociation. Ionization Ionization Storage Level: T

Página 133

216 High Edge Offset: The integer value step to optimize the ejection of the mass just above the parent ion mass. The High Edge Offset range is -2

Página 134

217 Dissociation Excitation Time: The excitation time is the time required for collision-induced dissociation (CID) by ion excitation. The excitat

Página 136

218 High Edge Offset: This parameter provides a fine adjustment for the isolation window to optimize the ejection of the mass just above the paren

Página 137

219 NOTE: This value is not used if the nonresonant CID method is selected. A value of 0 gives a fixed rf storage field, i.e., no modulation Mod

Página 138

220 Increase or decrease the CID (excitation) amplitude until a change in the spectra is observed. In the case of nonresonant CID, use 10 volt ste

Página 139 - 3900 GC Injecting Multiple

221 Automated Methods Development Automated Method Development (AMD) is used to optimize CID conditions for product ion formation in a MS/MS met

Página 140

222 It is a good idea to verify that the parent ion is isolated without a large loss in intensity. This can be done by setting the excitation amp

Página 141

223 Determine the optimum rf level by plotting the product ion intensity data as a function of CID (excitation) amplitude for different rf levels

Página 142

224 MS/MS You can do multiple reaction monitoring by adding lines of different parent ions masses and different dissociation parameters. The limit

Página 143

225 First, work out optimized conditions for MS/MS of the first parent ion. AMD will make this process go faster. Then optimize the conditions fo

Página 145

227 2000 MS Method Section Overview In the 2000 MS Configuration section, you configured your hardware for a 2000 and opened the System Control Wi

Página 146

21 MS Workstation Toolbar Options Moving the MS Workstation Toolbar The MS Workstation Toolbar can be moved to any edge of the Windows screen. Cli

Página 147 - System Control Menus

228 You will first be asked to select the instrument configuration for which you want to create a method. Select Instrument 1 for the 2000 modul

Página 148 - Edit Menu

229 You will be asked to select the channels on which post-run processing will be performed. When you have selected the data channels and type(s

Página 149 - Automation Menu

230 The Method Builder Window As you step down through the Method tree, the parameters associated with each section of the Method are displayed fo

Página 150 - Instrument Menu

231 The 2000 MS Method Windows Under the Method Directory item 2000 Mass Spec Control, click on the item MS Method Editor. The display on the righ

Página 151 - Windows Menu

232 Generally, Method Segment 1 is a Filament/Multiplier Delay. This segment will be acquired with the filament and multiplier turned off to prote

Página 152 - Help Menu

233 Click on the Special Application button. From within the Special Application dialog, one may specify that data should be acquired in Profile

Página 153 - System Control Toolbar

234 You now see additional tab dialogs for Segment Setpoints and Ionization Mode. Examine the parameters, which may be adjusted in the Segment Set

Página 154

235 2000 MS Method System Control The Startup Method When you enter System Control and display the Saturn System Control Window, the Startup1.mth

Página 155 - Functions

236 Editing Methods from the Saturn Status and Control Window The Saturn System Control or Acquisition Window contains a "Method:" butto

Página 156

237 Click on the Endtime button. Enter the new end time and click on OK. Importing Method Sections You may wish to copy sections from one Saturn

Página 157 - Ionization

22 Move to Windows Taskbar You can display the MS Workstation Toolbar as a Windows Taskbar icon. Taskbar icons appear in the lower right (or botto

Página 158

238 When the desired sections have been highlighted, click on the Import button to import them into the Method being edited. If the Method alread

Página 159

239 When the desired sections have been highlighted, click on the Delete button to delete them from the Method being edited. You will prompted to

Página 160 - The CI Parameters

240 After a Method has been password protected, the password will be required to save changes to the Method. Once a Method is password protected,

Página 161 - Maximum reaction time

241 3800 GC Method Command Reference 3800 GC AutoSampler When the 8400 AutoSampler or 8410 AutoInjector is selected, the AutoSampler window may c

Página 162 - Prescan Ionization Time

242 Item Description AutoSampler Type 8400, 8410, or None Specifies whether or not an 8400 AutoSampler or 8410 AutoInjector is installed on the

Página 163

243 Item Description Vial I, II, or III Specifies which of the three solvent vials will be used by the Default Cleaning Volume (uL) 0 to 10.0

Página 164 - Using Liquid CI Reagents

244 Internal Standard Section Item Description Use Yes or No If Yes, an internal standard addition will be used. When internal standard addition

Página 165 - Choice of Liquid CI Reagents

245 More User Defined Settings Dialog Box This dialog box is accessed from “More User Defined…” button that is displayed when the User Defined mo

Página 166

246 User Defined Settings Item Description Fill Volume (uL) 0 to 10.0 µL with 10 µL syringe 0 to 5.0 µL with 5 µL syringe Specifies the sample

Página 167 - Than Methane

247 Item Description Inject Speed (uL/sec) 0.1 to 50.0 µL per second with 10 µL syringe 0.1 to 25.0 µL per second with 5 µL syringe Specifies the

Página 168 - Tuning for CI Operation

23 This dialog box allows you to select which Saturn GC/MS Workstation instrument modules are available from this Workstation. When an instrument

Página 169 - Recommended Reading

248 3800 GC Sample Delivery Item Description Front Valve Oven Middle Valve Oven Rear Valve Oven The 3800 GC can have up to three valve ovens inst

Página 170

249 3800 GC Injector Item Description Front Injector Middle Injector Rear Injector The 3800 GC can have up to three injectors installed (front, m

Página 171 - Reference

250 1061 Injector Item Description Injector Oven On or off Turns the 1041 injector oven in the selected position on or off. Temperature (C) 50-

Página 172 - The flow sampling segment

251 Item Description Rate (C/min) 1-200 ºC /min The Rate in the first row is always blank and cannot be edited. Hold (min) 0.01-999.99 min Total

Página 173 - Ion Preparation

252 SPT Item Description Injector Coolant On or Off Turns the coolant valve on when the SPT injection device is cooling down. The cryogenic will

Página 174 - Segment Setpoints

253 3800 GC Flow/Pressure Item Description Front EFC Middle EFC Rear EFC The 3800 GC can have up to three injector EFC modules installed (front,

Página 175 - Ionization Mode - EI Auto

254 Item Description Pressure (psi) 0.1-100.0 psi Rate (psi/min) 0.01- 400.00 psi/min The Rate in the first row is always blank and cannot be e

Página 176 - Ionization Mode - EI Fixed

255 Type 4 (for valved systems) Item Description Pressure (psi) Pressure spreadsheet 100.0 psi Rate (psi/min) 0.1-100.0 psi/min The Rate in the

Página 177

256 3800 GC Column Oven Item Description Column Oven Coolant On or Off. Specifies whether or not the column coolant will be used. Enable Coolan

Página 178 - CI Fixed Parameters

257 3800 GC Detector Item Description Front Detector Middle Detector Rear Detector The 3800 GC can have up to three detectors installed (front, m

Página 179 - Customize SIS

24 Run Application This hierarchical menu item lists all applications showing on the MS Workstation Toolbar. When you select an item from this lis

Página 180 - The MS/MS Ion Prep Method

258 FID Detector Item Description Detector Oven On or off. Turns the detector oven on or off. Electronics On or Off. Indicates whether the ins

Página 181 - Item Description

259 TCD Detector Item Description Detector Oven On or off. Turns the TCD oven on or off. Electronics On or Off. Indicates whether the installed

Página 182 - Customize Resonant Method

260 Item Description Time Constant Slow or Fast. Carrier Gas He or N2/Argon. Filament Temp Limit (C) 390 or 490 C. EFC Type None, Type 13, Typ

Página 183

261 Item Description Autozero Yes or No. Set to yes at initial time means that the TSD Autozero is on continuous before the run starts. Autozero

Página 184

262 ECD Detector Item Description Detector Oven On or off. Turns the TCD oven on or off. Electronics On or Off. Indicates whether the installed

Página 185 - Ion Preparation MS/MS

263 Item Description Methanizer Oven On or Off. Temperature (C) 450 C. PFPD Detector Item Description Detector Oven On or off. Turns the PFPD

Página 186

264 Item Description Sort Sorts the spreadsheet rows by time. Photomultiplier Voltage (V) 300- 900 V. Gate Delay (msec) 20 msec. Gate Width (mse

Página 187

265 3800 GC Output Item Description Port A Port B Port C The 3800 GC can have up to three output ports installed (A, B, and C). The tabs at the t

Página 188

266 3800 GC Data Acquisition Item Description Detector Bunch Rate Powers of 2 from 1 to 128 points. Sets the detector bunch rate in numbers of

Página 189

267 3800 GC Method Section Overview In the 3800 GC Configuration section, you configured your hardware for an instrument and opened the System Con

Página 190

25 2000 MS Module Control Starting System Control the First Time Before you enter System Control for the first time, confirm that the proper instr

Página 191 - 2000 MS Method Electron

268 If you choose Create a New Method File, the Star Assistant Wizard will guide you in building this new method. You will first be asked to sel

Página 192 - AGC Prescan

269 Select the detectors for post-run processing. For each detector in the Method, you will be asked to select the channels on which post-run p

Página 193 - Mass Scanning

270 When you have selected the data channels and type(s) of post-run processing to be run for each detector, the Star Assistant will create a Met

Página 194

271 The parameters window shows the parameters for the highlighted item in the navigation window. Method parameters are viewed and edited in this

Página 195 - Software Parameters

272 The 3800 Method section contains seven Method windows: Sample Delivery, Injector, Flow/Pressure, Column Oven, Detector, Output, and Detector

Página 196

273 Select rows by clicking and dragging on the row numbers on the left side of the spreadsheet. One or more rows can be selected by clicking and

Página 197 - Ionization Time Factor

274 When the Method is downloaded to the 3800 GC, component program end times that exceed the column oven end time will be truncated. Sample Del

Página 198 - Background Mass

275 Indicate whether or not you will use the installed Valve Oven by clicking on the “On” or “Off” radio buttons. Use the spreadsheet to build

Página 199

276 Injector Window The Injector window contains up to three Injector Programs (Front, Middle, Rear). Use the Injector Programs to specify the tem

Página 200

277 If you indicate that Coolant is turned on, specify the desired “Enable Coolant at” temperature and “Coolant Timeout”. Use the spreadsheet to b

Página 201 - The Ion Preparation Method

26 Refer to the installation instructions packaged with your Ethernet card for information on installing the Ethernet card in your computer. Befor

Página 202

278 You can use a spit ratio of 100 after injection to vent the injector of any residual solvent. Use a very low split ratio after flushing to con

Página 203

279 You can use a split ratio of 100 after injection to vent the injector of any residual solvent. Use a very low split ratio after flushing to c

Página 204

280 Indicate whether or not you will use the installed 1061 Injector by clicking on the “On” or “Off” radio buttons. If you indicate that a 1061

Página 205

281 Flow/Pressure Window The Flow/Pressure window contains up to three EFC Programs (Front, Middle, Rear). Use the EFC Programs to specify the pre

Página 206 - Autoscale Waveform

282 The first row of the spreadsheet contains the Initial pressure and hold time for the Type 1 EFC. The EFC will equilibrate to this setting when

Página 207 - Tips for Using SIS

283 Type 3 EFC (for 1041/1061 Injectors) If you indicate that a Type 3 EFC is installed, a flow ramp spreadsheet will appear. The first row of th

Página 208

284 Type 4 EFC (for Valved Systems) If you indicate that a Type 4 EFC is installed, a pressure ramp spreadsheet and a flow time program spreadshee

Página 209 - Theory of Operation

285 Column Oven Window The Column Oven window contains the Column Oven Program. Use the Column Oven Program to specify the Coolant Parameters and

Página 210 - Product Ion Formation

286 Detector Window The Detector window contains up to three Detector Programs (Front, Middle, Rear). Use the Detector Programs to specify the ope

Página 211

287 Indicate whether or not you will use the installed FID Detector by clicking on the “On” or “Off” radio buttons. If you indicate that an FID

Página 212

27 The Network dialog box is displayed. 3. If TCP/IP is already listed in the list of network components, skip to the Note after step 5, otherwi

Página 213 - Summary

288 Program the Methanizer in the position corresponding to the tab in the Detector window by clicking on the Methanizer button. The Methanizer

Página 214

289 If you indicate that an TCD Detector is to be turned on and heated, select the desired Temperature and Filament Temperature setting. Indica

Página 215

290 Micro-TCD Detector If you indicate that a Micro-TCD Detector is installed, an Oven Power switch and an Electronics switch will appear in the t

Página 216 - The MS “q” Calculator

291 TSD Detector If you indicate that a TSD Detector is installed, an Oven Power switch, an Electronics switch, a Temperature setting, a Bead Curr

Página 217 - Isolation

292 ECD Detector If you indicate that an ECD Detector is installed, an Oven Power switch, an Electronics switch, and a Temperature setting will ap

Página 218

293 PFPD Detector If you indicate that a PFPD Detector is installed, an Oven Power switch, an Electronics switch, Square Root Mode switch, and a T

Página 219

294 Output Window The Output window contains up to three Output Port Programs (Port A, Port B, Port C). Use the Output Port Programs to time progr

Página 220 - Dissociation

295 Data Acquisition Window The Data Acquisition window contains instructions for collecting a baseline noise sample (Noise Monitor) and for selec

Página 221

296 Autosampler Window The Autosampler window contains sampling parameters for the 8400/8410 Autosampler when attached to the 3800 GC. The paramet

Página 222

297 Auto-Configuring the Method to Match the 3800 GC Hardware When you edit a 3800 GC Method while the corresponding GC is online in System Contro

Página 223

1 Contents Getting Started...

Página 224 - Product ion 2

28 The Select Network Protocol dialog box is displayed. 5. Select Microsoft as the manufacturer. Select TCP/IP as the protocol. Click OK. The pr

Página 225 - Using Nonresonant Excitation

298 You are then prompted for the name of the file under which to save the Method. The active Method in System Control is updated to reflect the p

Página 226 - MS/MS/MS

299 Once you have edited the Method and closed the Method Builder window, you are prompted to reactivate the Method. Reactivating the Method downl

Página 227

300 When the desired sections have been highlighted, click on the Import button to import them into the Method being edited. If the Method alread

Página 228

301 When the desired sections have been highlighted, click on the Delete button to delete them from the Method being edited. You will prompted to

Página 229 - 2000 MS Method Section

302 After a Method has been password protected, the password will be required to save changes to the Method. Once a Method is password protected,

Página 230

303 3800 GC System Control Command Reference Status and Control Window The 3800 Status and Control window is divided into five display areas. The

Página 231

304 graphical representation of the 8400 or 8410 Carrousel. This display graphically shows which vials are to be sampled, which vials have been sa

Página 232 - The Method Builder Window

305 Temp Zones Status Display The temperature zones status display is in the middle portion of the 3800 Status and Control window. The display in

Página 233 - The 2000 MS Method Windows

306 Column Oven Status: Item Description Ready Yes or No. The column oven is Ready (Yes) if the setpoints have been achieved and stabilized. The

Página 234

307 AutoSampler Status: This option is only shown on 3800 GCs that have an 8400 AutoSampler or 8410 AutoInjector connected to them. Item Descript

Página 235 - The Flow Sampling Segment

29 Enter an IP address in the range 10.2.128.1 through 10.255.255.254. Note that if you are adding more than one Workstation to this network, eac

Página 236

308 Sample Delivery Status: Item Description Valve 1 through Valve 7 If the valves are configured in the 3800 GC, displays the assigned valve na

Página 237 - The Startup Method

309 1177 Injector Status: Item Description Ready Yes or No. The 1177 injector oven is Ready (Yes) if the setpoints have been achieved and stabili

Página 238 - Status Window

310 Item Description Displays the actual temperature of the 1079 injector oven at the 3800 GC. Split State On or Off. Displays the current split

Página 239 - Importing Method Sections

311 SPT Injector Status: Item Description Ready Yes or No. The SPT injector oven is Ready (Yes) if the setpoints have been achieved and stabilize

Página 240 - Deleting Method Sections

312 Item Description Displays if a fault in the Type 1 EFC component has occurred. Type 1 Pressure Setpoint 0.1 to 100 psi Displays the programmed

Página 241 - Password Protecting a Method

313 Type 4 Injector EFC Flow/Pressure Status: Item Description Ready Yes or No. The Type 4 Injector EFC component is Ready (Yes) if the setpoint

Página 242

314 Item Description Displays the TCD Range initial condition setting or the time-programmed setting in the active method. Time Const Fast (50

Página 243 - 3800 GC Method Command

315 Item Description microTCD Adjustments in the active method. Current Displays, in mA, the actual microTCD current. Balance Pct Displays, in %

Página 244 - Default Clean Section

316 GC. Bunch Size Displays the data acquisition bunch size. Freq Displays the data acquisition bunch rate, in Hz.

Página 245 - Clean Mode Section

317 ECD Status: Item Description Ready Yes or No. The ECD detector is Ready (Yes) if the setpoints have been achieved and stabilized. The ECD det

Página 246 - Internal Standard Section

30 Ensure that no entries have been made in your Gateway, and that Domain Name Server (DNS) and WINS Configuration have been disabled. These entri

Página 247 - Solvent Plug Settings

318 Item Description TSD Bead Power On or Off Displays the TSD Bead Power initial condition setting or the time-programmed setting in the active

Página 248 - Viscosity Settings

319 Type 11 Detector EFC Status: Item Description Type 11 Displays the Detector EFC type. Detector EFC Type 11 has 3 channels and is used for FID

Página 249

320 Type 13 Detector EFC Status: Item Description Type 13 Displays the Detector EFC type. Detector EFC Type 13 has 1 channel and is used for eithe

Página 250 - 3800 GC Sample Delivery

321 Type 15 Detector EFC Status: Item Description Type 15 Displays the Detector EFC type. Detector EFC Type 15 has 3 channels and is used for PFPD

Página 251 - 3800 GC Injector

322 8400/8410 Carrousel Display When an 8400 AutoSampler or 8410 AutoInjector is connected to your 3800, the Carrousel display will be visible in

Página 252 - 1079 Injector

323 Chromatogram Display Toolbar Shows or hides the toolbar. Full Scale: zooms all traces to their full scale values. This button is the same

Página 253 - Spilt Ratio Dialog Box

324 Chromatogram Zooming and Scrolling The following mouse actions are possible for the chromatogram display window: Action Effect of Action Lef

Página 254

325 8400/8410 Dual Mode Setup Dialog Box When the 8400 AutoSampler or 8410 AutoInjector is used in Dual Mode, this dialog box is used to assign

Página 255 - 3800 GC Flow/Pressure

326 Field Description 8400/8410 Mounting Position (Informational entry only) Front or Rear When set to match the physical mounting location of th

Página 256

327 Setup Ethernet Ports Dialog Box This dialog box is displayed the first time that the Star Assistant guides you through the setup of your 3800

Página 257 - Type 4 (for valved systems)

31 Contact your Network Administrator (or whoever assigns IP addresses for your network) to see what the appropriate settings are for your Gatewa

Página 258 - 3800 GC Column Oven

328 Setup... Click to setup IP address management (BOOTP Server). The Setup BOOTP Server Dialog Box is displayed. Select the Workststion IP Add

Página 259 - 3800 GC Detector

329 Field Description dialog box to avoid inadvertent or unauthorized changes to IP address assignments. If this item is checked, the next time y

Página 260 - FID Detector

330 Advanced BOOTP Settings Dialog Box Item Description Assign Private Class A addresses to Hosts Manually Checked or not checked Determines whe

Página 261 - TCD Detector

331 Field Description 2nd Sample Name (Dual Mode operation only)Up to 19 characters Sets the name of the second sample injected. This column is on

Página 262 - TSD Detector

332 Field Description injection positions, entering the wrong position will cause the sample line to be skipped and a “Bad Injector” message enter

Página 263

333 3900 GC Method Command Reference 3900 GC AutoSampler When the 8400 AutoSampler or 8410 AutoInjector is selected, the AutoSampler window may c

Página 264 - ECD Detector

334 Item Description AutoSampler Type 8400, 8410, or None Specifies whether or not an 8400 AutoSampler or 8410 AutoInjector is installed on the

Página 265 - PFPD Detector

335 Item Description Vial I, II, or III Specifies which of the three solvent vials will be used by the Default Cleaning Volume (uL) 0 to 10.0

Página 266 - Methanizer Dialog Box

336 Internal Standard Section Item Description Use Yes or No If Yes, an internal standard addition will be used. When internal standard addition

Página 267 - 3800 GC Output

337 More User Defined Settings Dialog Box This dialog box is accessed from “More User Defined…” button that is displayed when the User Defined mo

Página 268 - 3800 GC Data Acquisition

32 Configuring the 3800 or 3900 GC Communication (No Company Network) Use the following instructions if either a 3800 or 3900 GC and Varian MS Wor

Página 269 - 3800 GC Method Section

338 Item Description Vial I, II, or III Selects which solvent vial to use for the solvent plug. Volume (uL) 0 to 10.0 microliters with 10 uL sy

Página 270 - MS Workstation

339 Item Description Fill Volume (uL) 0 to 10.0 microliters with 10 uL syringe 0 to 5.0 microliters with 5 uL syringe Specifies the sample volum

Página 271

340 Default Settings for Predefined AutoSampler Modes The following table lists the parameter settings used for each of the Predefined 8400/8410 m

Página 272

341 3900 GC Injector Section 1177 Injector Item Description Injector Oven On or off. Turns the 1177 injector oven in the selected position on or

Página 273 - The 3800 GC Method Windows

342 Item Description Time 0.00 to 999.99 min. Split State On/Off. If the split state is ON, then the sample is split according to the split rat

Página 274 - Spreadsheet editing

343 3900 GC Flow/Pressure Section Type 1 (for 1177 injector) Item Description Pressure (psi) 0.1 to 100.0 psi. Rate (psi/min) 0.01 to 400.00 ps

Página 275 - Checking Method End times

344 3900 GC Column Oven Section Item Description Stabilization Time (min) 10.0 min. Specifies the column Stabilization Time. Temp (C) 30 - 450

Página 276 - Sample Delivery Window

345 3900 GC Method Section Overview In the 3900 GC Configuration section, you configured your hardware for an instrument and opened the System Con

Página 277

346 If you choose Create a New Method File, the Star Assistant Wizard will guide you in building this new method. You will first be asked to sele

Página 278 - Injector Window

347 For each detector in the Method, you will be asked to select the channels on which post-run processing will be performed.

Página 279

33 From the Setup Ethernet Ports, click Setup for IP Address Management [BOOTP Server]. Click Setup. When the Setup BOOTP Server dialog box is

Página 280 - 1177 Injector

348 When you have selected the data channels and type(s) of post-run processing to be run for each detector, the Star Assistant will create a Met

Página 281 - 1041 Injector

349 Detailed information about the menu items and Toolbar buttons can be found in the online help. Method Notes The first item in the Method is t

Página 282 - SPT Injection Device

350 The 3900 Method section contains two Method windows: GC Control, and Autosampler. These windows contain all parameters that control the oper

Página 283 - Flow/Pressure Window

351 One or more rows can be selected by clicking and dragging on this column. Spreadsheets that specify time programs can display duplicate times

Página 284

352 GC Control Window The GC control window contains sections (Flow/Pressure, Injector, and Column Oven). Flow/Pressure Section Use the EFC Progra

Página 285

353 Rows after the first row of the spreadsheet contain the programmed settings for each of the ramp segments. Each segment will ramp to the speci

Página 286 - Flow spreadsheet

354 1177 Injector With a 1177 Injector is installed, an Oven Power switch, a Temperature setting and a Split Ratio table will appear. Indicate w

Página 287 - Column Oven Window

355 You can use a split ratio of 100 after injection to vent the injector of any residual solvent. Use a very low split ratio after flushing to c

Página 288 - Detector Window

356 Specify the desired Stabilization Time. Use the spreadsheet to build a temperature ramp program to heat and/or cool the Column Oven. The first

Página 289

357 available. Selecting User Defined mode allows you access to all 8400 autosampler parameters to fine-tune your injection. Consult the Online He

Página 290

34 Click the Manage IP addresses from this Workstation checkbox to manage your GC’s IP address from this Workstation. As the GC is turned on, it

Página 291

358 To upload the Method from the 3900 GC to System Control, select “Upload Active Method from Modules…” from the File menu. You are then promp

Página 292 - Micro-TCD Detector

359 Method… button When you click on this button Method Builder is opened with active Method loaded and the corresponding Instrument Module selec

Página 293

360 import by clicking on them. If you click on one section and the hold down the shift key while clicking on another section, all of the sections

Página 294

361 A dialog box of sections contained in the Method file is displayed. Highlight the sections that you wish to delete by clicking on them. If y

Página 295

362 Printing the Method To print a method from Method Builder, click on the Print button on the Toolbar and select the Method section or sections

Página 296 - Output Window

363 3900 GC System Control Command Reference Status and Control Window The 3900 Status and Control window is divided into four display areas. The

Página 297 - Data Acquisition Window

364 Item Description Runtime Shows the elapsed time in minutes since the beginning of the run. The maximum run time is 999.99 minutes. Endtime S

Página 298 - Autosampler Window

365 Item Description Col Oven Setpoint Abient+5 °C to 450 °C Displays the column oven programmed temperature setting in the active method. Col O

Página 299 - Hardware

366 Item Description Stabilization Time 0.00 - 10.00 min Shows the 3900 GC column oven stabilization time in minutes. The stabilization time coun

Página 300

367 Item Description Linear Velocity Displays, in cm/sec, the column linear velocity calculated from the column head pressure, column temperature

Página 301

35 Click System Control/Automation. When System Control has started for the first time, the Star Assistant Communication Configuration Wizard will

Página 302

368 when it is activated. It also allows the configuration of the 3900 GC to be changed from the Saturn GC/MS Workstation. Item Description Colu

Página 303

369 Item Description splitless runs in which the split vent is opened.Injector EFC, Gas Saver Flow The lowest system flow rate that will be maint

Página 304

370 Item Description poor operation but will not harm either the GC or the AutoSampler. AutoSampler, Syringe Speed 1 to 30 (cm/sec), default=30 T

Página 305 - Command Reference

371 Item Description Calibrate Vial 0 Position, Start Calibration To start the Vial 0 (or Vial 1) calibration, make certain a vial with the same

Página 306 - 3800 Operation Display

372 Item Description always approach the final calibration position with clockwise movements. To help facilitate this rule, the carrousel will bac

Página 307 - Component Status Display

373 Item Description needle guide, so this height will give you optimum penetration depth.). Calibrate Injector Position, Start Calibration Press

Página 308 - Column Oven Status:

374 Item Description Calibrate Vial 0 Position, Start Calibration To start the Vial 0 (or Vial 1) calibration, make certain a vial with the same

Página 309 - AutoSampler Status:

375 Item Description Calibrate Vial 0 Position, Use Mouse Buttons to Rotate Carrousel Clicking this button will display the following dialog box

Página 310 - Name Default State Energized

376 Item Description Calibrate Injector Position, Use Mouse Buttons to Raise/Lower Syringe Using the Syringe Up button adjust the height of the n

Página 311

377 Setup Ethernet Ports Dialog Box This dialog box is displayed the first time that the Star Assistant guides you through the setup of your 3900

Página 312 - 1041/1061 Injector Status:

36 From the Setup Ethernet Ports dialog box select Setup to display the BOOTP Server dialog box. Select Setup to display the BOOTP Server dial

Página 313 - SPT Injector Status:

378 Item Description Actual IP Displays the actual IP address of the connected 3900 GC. Setup... Click to setup IP address management (BOOTP Ser

Página 314

379 Item Description Manage IP addresses from this Workstation Checked or not checked When IP addresses are managed from a central location by a

Página 315

380 Advanced BOOTP Settings Dialog Box This dialog lets you enter advanced settings. Item Description Assign Private Class A addresses to Hosts

Página 316

381 8200 AutoSampler Instrument Control Command Reference 8200 AutoSampler Status and Control Window

Página 317 - FID Status:

382 Item Description RunTime The elapsed time since the start of the run. EndTime The time when the AutoSampler Method will end. Mode Standard

Página 318

383 AutoSampler Carrousel Display Item Description Black dot Indicates the vials found during Vial Check. Red fill Indicates vials listed in t

Página 319 - TSD Status:

384 Hardware Dialog Box Item Description Sampling Device Specifies the size and type of syringe installed in the 8200 AutoSampler, either a 10 m

Página 320 - PFPD Status:

385 8200 SampleList Window Extensions When an 8200 is controlled by the Varian MS Workstation, the SampleList for that instrument contains the fol

Página 321

386 Item Description Volume 0.1 to 10 ul with 10 ul syringe, or 1 to 100 ul with 100 ul syringe Sets the volume in microliters to be drawn into t

Página 322

387 Carrousel Dialog Box Item Description Copy Replaces the entire SampleList with a copy of the Default Sample parameters for each vial in the

Página 323

37 NOTE: If more than one Workstation is being connected on the same network, only one Workstation should manage the IP addresses for all GCs conn

Página 325 - Chromatogram Display Toolbar

389 8200 Method Command Reference 8200 Configuration Window Item Description Carrousel Type 12 Vials or 48 Vials Select the tray that is to be

Página 326 - 3800 Setup Dialog Box

390 Item Description Volatile Sample Used with samples in a high vapor pressure solvent. A solvent flush sampling mode with slow plunger speeds a

Página 327

391 User Defined Parameters Item Description Solvent Flush Sampling When Yes is selected, the solvent plug size needs to be specified and wheth

Página 328 - Field Description

392 Item Description Pause Time (sec) 1 to 30 seconds Sets the amount of time that the syringe will be held in the vial after the sample is drawn

Página 329

393 Automated MS Report Generation Overview Once you have added Report sections to your Method, automated reports can be generated from System Con

Página 331

395 Automation File Editor Command Reference Menus File Menu Menu Item Description New A sub-menu displays RecalcList, SampleList and Sequence.

Página 332

396 Edit Menu Menu Item Description Cut Deletes a selection and copies it to the Clipboard. Used to remove or move a selected part of a spreadsh

Página 333

397 Main Toolbar Item Description A sub-menu displays RecalcList, SampleList and Sequence. Selecting one of them displays the Create a New Auto

Página 334

2 Specifying Per-Sample Data Handling Parameters ...10

Página 335 - 3900 GC Method Command

38 When the Assign # IP addresses starting from: #.#.#.# radio button is selected, the bottom portion of the dialog changes. You may select to co

Página 336

398 Open Automation File Dialog Box This dialog box is used to specify or open an automation file. The Open Automation File dialog box appears wit

Página 337

399 Save Automation File As Dialog Box This dialog box is used to name an automation file. The Save Automation File As dialog box appears with sev

Página 338

400 Print Setup Dialog Box This dialog box is used to specify the printers that will be used by Varian MS Workstation applications both interactiv

Página 339

401 Edit Notes Dialog Box This dialog box allows you to enter descriptive notes associated with an automation file. These notes can be viewed when

Página 340

402 RecalcList Window Data Files can be added to a RecalcList by clicking on a cell in the Data File column and typing the file name, or by pressi

Página 341

403 Item Description AutoLink... Two AutoLink commands when Sample Type is Baseline, Analysis, Calibration, or Verification. One AutoLink comman

Página 342

404 Item Description Defaults… Displays the Set Defaults dialog box, allowing you to specify default values for each applicable field in the Reca

Página 343 - 3900 GC Injector Section

405 Item Description Detector Channel Indicates the detector channel that is specified by the remaining fields in the row. Channels are indicated

Página 344

406 Item Description Amount Standard 2-8 0.000001 to 1,000,000 Sets the amounts of the second through eighth internal standards. Used to calibrat

Página 345 - Type 1 (for 1177 injector)

407 Open Data File Dialog Box Item Description Look in Lists the available folders and files. To see how the current folder fits in the hierarc

Página 346 - 3900 GC Column Oven Section

39 The Instrument menu is displayed. Press 1 to select the Remote/ Local Control screen. The Ethernet address, IP address and Alias (which may not

Página 347 - 3900 GC Method Section

408 Item Description Open File Opens the selected data file using the selected channel. Cancel Cancels file selection. SampleList Window The Sa

Página 348

409 Item Description AutoLink Two AutoLink commands when Sample Type is Baseline, Analysis, Calibration, or Verification. One AutoLink command w

Página 349

410 Item Description Data Files… Opens the Data File Generation dialog box to specify the naming scheme being used for Data Files generated from

Página 350

411 Data File Generation Dialog Box Item Description Directory for Data Files Shows the currently selected directory where Data Files will be

Página 351 - The 3900 GC Method Windows

412 RecalcList Generation Dialog Box Item Description Do not automatically create and update a RecalcList. No RecalcList will be generated or upd

Página 352

413 AutoLink Parameters Dialog Box With AutoLink, you can specify a program to be executed after all injections of a sample have been performed, o

Página 353

414 Sequence Window Item Description Action Shows the action chosen for each line in the Sequence Method Shows the Method chosen for each li

Página 354 - GC Control Window

415 Automation File Editor Overview The Automation File Editor is used for editing and creation of SampleLists, RecalcLists, and Sequences outside

Página 355 - Injector Section

416 …or by clicking on the New or Open Automation File button on the toolbar. The RecalcList window for the open RecalcList is displayed. It conta

Página 356

417 Editing or creating a SampleList Choose either a New SampleList or Open an existing SampleList from the File menu.. …or by clicking on the N

Página 357 - Column Oven Section

40 Ethernet Ports dialog box is not displayed, select the Setup Ethernet Communications menu item from the Instrument menu to display the Star Ass

Página 358

418 Enter notes about the sample. Enter post-run operations to be performed. Enter information about the samples you plan to inject. Select the l

Página 359

419 If you need to add several similar lines to the sample list, click on the Add Lines… button. You can then enter the common information in the

Página 360

420 Specifying Per-Sample Data Handling Parameters Most Data Handling parameters are specified in the Method used during the injection. Some param

Página 361

421 Specifying a RecalcList From the SampleList RecalcList… button, you can choose to create a new RecalcList, append to an existing RecalcList, o

Página 362

422 Using More Than One Method for Injections The Varian MS Workstation allows you to perform automated injections using more than one Method. The

Página 363

423 Editing or Creating a Sequence Choose either a New Sequence or Open an existing Sequence from the File menu... …or by clicking on the New or

Página 365 - 3900 GC System Control

425 GC Batch Report Overview The Batch Report application allows you to quickly generate reports for a batch of Data Files without using System Co

Página 366

426 Method Selection The Batch Report application allows you to generate reports for a set of Data Files using parameters specified in a Method.

Página 367 - Oven Status Display

427 Generating Reports To generate reports for Data Files using the report formatting information in the specified Method drag Data Files from th

Página 368 - Injector EFC Status Display

41 Adding a GC and Varian MS to the Instrument in System Control Once you have configured your Workstation computer and 3800 or 3900 GC for networ

Página 369 - 3900 Setup Dialog Box

428 The Change Application dialog box displays all post-run applications registered in the Star32.ini file in your Windows directory. The actual

Página 370

429 GC Data Handling Calibration Types of Calibration There are three types of calibration available with the Varian MS Workstation: External Stan

Página 371

430 Specify the calibration type. Up to 10 separate replicates. Percent of new versus historical data. Refer to the on-line help in Interactive Gr

Página 372

431 Specify internal standard amounts. You can also calibrate your Method using previously collected Data Files, recalculating them as calibration

Página 373

432 You may also view Calibration Curves for the active Method in Interactive Graphics. Pull down the Results menu. Select View Calibration Curv

Página 374

433 Select View Curves. Generating Calibration Block Reports As you create calibration information in System Control, you may wish to generate a

Página 375

434 Calibration Verification You may wish to periodically check the validity of your calibration data as you perform analytical injections. You do

Página 376

435 GC Data Handling Fundamentals Introduction Even after optimizing your chromatographic conditions to provide the best separation possible, you

Página 377

436 Peak Detection The Varian MS Workstation software reduces the raw data collected from the chromatograph into a results report in four steps: 

Página 378

437 programs a new, wider peak width. Although it is rarely necessary, the software is also able to automatically program narrower peak width sett

Página 379

42 This 3800 GC is connected to Port 44. The status indicates the availability of the GC. The IP address of the GC is shown here. Click OK, and w

Página 380

438 otherwise it is considered a main peak. The rule of thumb is that the higher the programmed Tangent Percentage value, the more peaks are consi

Página 381

439 Identifying Peaks Peaks are identified with the use of the Peak Table in the Data Handling section of the Method. The main purpose of the Peak

Página 382

440 Calibration Curve ReportFile: c:\star\tutorial\ext std.mthDetector: ADC Board, Address: 16, Channel ID: B2-OctanoneExternal Standard AnalysisR

Página 383 - Control Command Reference

441 Internal Standard Calibration When you use the Internal Standard calibration type, you calibrate with regular calibration standards but you al

Página 385

443 GC Data Handling Method Command Reference Integration Parameters Peak Detection: Item Description Subtract Blank Baseline checked or not che

Página 386 - Hardware Dialog Box

444 Item Description Initial Tangent Height % 0 to 100 Sets the percentage of a mother peak's size below which a given peak is considered a

Página 387 - Automix Routines Dialog Box

445 Peak Table Item Description Retention Time 0.001 to 1440.0 Sets the expected retention time of a peak. Specify a retention time at which yo

Página 388

446 Item Description Define Peak Windows... Opens the Define Peak Windows dialog box to set time windows for reference peaks and other peaks or to

Página 389 - Carrousel Dialog Box

447 Calibration Setup Item Description Calibration Type % (No Calibration), Internal Standard (IS), External Standard (ES), Normalized % (N%)

Página 390

43 Elements of the Configuration Screen After the 3800 or 3900 connects to System Control, configure it in an Instrument by moving its icon from t

Página 391 - 8200 Configuration Window

448 Item Description Weighted Regression None, 1/n, 1/nX, 1/X2, or 1/nX2 Sets the weighted regression scheme to be used in determining calibratio

Página 392 - Liquid Sampling Options

449 Item Description Edit/Lock Calibration Data... Opens the Coefficients window to edit calibration coefficients for the Method. Coefficients Tab

Página 393 - User Defined Parameters

450 Calibration Curve Window Item Description Curve Type Shows the type of curve fit currently used. Indicates whether the curve fit has been ch

Página 394 - SPME Options

451 Item Description Revert Undoes any changes to the curve since it was last saved. Peak Name Any peak in the chromatogram Selects a peak for

Página 395

452 Print All Dialog Box Item Description Curves Per Page 1, 2, 3, or 4 Lets you set how many curves will be printed on each page. Amount Units

Página 396

453 Item Description Save 2 Saves overlay curve 2 as the curve for the peak. Point Info Dialog Box Item Description Exclude Selected Point from

Página 397

454 Item Description Overlay Shows what the calibration curve would look like with changes to the coefficients by overlaying the new curve on the

Página 398

455 Item Description Deviation Tolerance 0.0 to 500 Sets the percentage of deviation from the calibration curve beyond which a result is consider

Página 399 - Main Toolbar

456 Item Description Delete Deletes the highlighted Time Events Table entry from the table. Sort Sorts the table in order of increasing start ti

Página 400

457 Event Description Forced Peak (FP) Forces integration between the start and end times. A resolved baseline is drawn from the amplitude of the

Página 401

44 Instrument Parameters, Instrument Name, Operator Name, and Instrument status are listed here. AutoStart Module area. Place the 8200 AutoSample

Página 403 - Edit Notes Dialog Box

459 GC Interactive Graphics Dialog Boxes Open Multiple Data Files Dialog Box NOTE: to quickly open files (when the file list spreadsheet is empty)

Página 404 - RecalcList Window

460 Item Description Look in Lists the available folders and files. To see how the current folder fits in the hierarchy on your computer, click

Página 405

461 Item Description Up Moves the selected item up one row. If there is already an entry in the row above, the two entries are exchanged with eac

Página 406

462 Open Method File Dialog Box Item Description Look in Lists the available folders and files. To see how the current folder fits in the hier

Página 407

463 Item Description Recent Files Click on this button to display a list of recently selected files. When you select a file from this list, its n

Página 408

464 Save Method As Dialog Box Item Description Save in Specifies the folder into which the method is to be saved. To see how the current folder

Página 409 - Open Data File Dialog Box

465 Saturn Printer Setup Dialog Box This dialog box is used to specify the printers that will be used by Varian MS Workstation applications both i

Página 410 - SampleList Window

466 Layout Tab Item Description Show X Axis Show or hide the time axis. Show Y Axis Show or hide the amplitude axis. Show Horizontal Scroll Ba

Página 411

467 Item Description Show Offset Perspective Displays perspective lines when more than one Data File is open in overlay mode and both the time an

Página 412

45 software versions (i.e. the forth software system). When the maximum number of non-fatal errors is exceeded during automation, the automation s

Página 413

468 Item Description Show Peak Names When checked, displays peak names in the Main Window for all reported peaks, so even unidentified peak names

Página 414

469 Item Description NOTE: all data points may not be drawn when zoomed to full or large scale. That is because the data is reduced at large sca

Página 415

470 Item Description Offset by If more than one chromatogram is open, enter the amount of vertical or horizontal spacing between chromatograms. T

Página 416 - Sequence Window

471 Item Description Save As … Saves the current color selection. This opens a dialog box into which you enter the name of the theme to save. Thi

Página 417 - Automation File Editor

472 Item Description Unidentified Peak Factor 0.00001 to 999999 Sets a calibration factor for unidentified peaks. Used to calculate results for u

Página 418

473 Item Description Update List or Update Amounts Copies the current list of internal standards and their amounts from the peak table to the tab

Página 419

474 Item Description Group Any integer Allows you to assign an arbitrary group number to a peak. A report can be generated organized by number. Am

Página 420

475 GC Interactive Graphics Menus File Menu Menu Item Description Add/Remove Chromatogram … Opens the Open Multiple Data Files dialog box to sele

Página 421

476 Menu Item Description Print Setup … Opens the Saturn Printer Setup dialog box to set preferences for printing. You can open the Print Setup

Página 422

477 Menu Item Description Main Toolbar Shows or hides the main application tool bar, which contains buttons such as the Add/Remove Chromatogram

Página 424

478 Edit Method Menu Menu Item Description Set Password … Opens the Add Password Dialog Box which allows you to add or change the password for

Página 425

479 Help Menu Menu Item Description Help Topics Displays the help you are now viewing. Product Support Web Site If you have Internet access and

Página 427 - GC Batch Report

481 GC Interactive Graphics Toolbars Toolbar Overview There are two toolbars on the main window: the Main Toolbar and the Method QuickLink Toolbar

Página 428 - Method Selection

482 Reintegrate Now/Clear Moved Events: same as Reintegrate Now, except that any user defined peak start and end points are reset before reintegr

Página 429 - Changing Report Commands

483 Previous Scaling: zooms to the previous time and amplitude range. Each time you scale chromatogram(s), Interactive Graphics adds the new scal

Página 431 - GC Data Handling Calibration

485 GC Interactive Graphics Window Locator Window Use the Locator Window to view the entire active chromatogram and to select a section of the chr

Página 432 - Automated Calibration

486 Main Window Use the Main Window to view and manipulate between one and seven chromatograms. This is the main window you use when working with

Página 433

487 2. Show a cursor and its associated “info-panel” containing the time and amplitude of the cursor and peak information. 3. Display baselines an

Página 434

47 2000 MS Instrument Control Command Reference Saturn Module Dialogs Saturn Module Keypad Dialog This dialog can be hidden by clicking on Hide K

Página 435 - Select View Curves

488 You can scale vertically using the Attenuation Control to the right of the Main Window. This adjusts the amplitude range on a logarithmic scal

Página 436 - Calibration Verification

489 When a peak event has been moved manually, peaks whose areas are affected by the moved event are marked in the report with a ‘U‘, designating

Página 437 - Performing a Pilot Run

490 Neither the position of an info-panel, nor the configured list of items are retained when the data file is closed and then reopened. These are

Página 438 - Peak Detection

491 Item Description File The full path name of the active chromatogram. Channel To displayed channel of the active chromatogram. Last recalc

Página 439 - Skimming Fused Peaks

492 Color Type of Peak Table Entry Blue Reference peak Red Standard peak Green Relative retention time peak Yellow None of the above – a norm

Página 440 - Forcing Peaks

493 Editing Peak Table Entries and Time Events You can later change any aspect of any time event or peak table entry by double clicking on an item

Página 441 - Building a Calibration Curve

494 Info Window and Mouse Cursor Types Moving the mouse and pausing over a time event in the Visual Method Edit Window brings up a window containi

Página 442

495 Action Effect of Action Right mouse button click on a peak table entry or time event. Brings up a context sensitive menu with actions to be t

Página 444

497 GC Interactive Graphics Viewing Chromatograms in Interactive Graphics Interactive Graphics is the Varian MS Workstation application that allow

Página 445 - GC Data Handling Method

3 System Control Toolbar...151 Main Toolbar...

Página 446

48 Spectrum Toolbar Click the green arrow t hide the toolbar. Click the upper left of the full screen display to restore the toolbar. Click f

Página 447 - Peak Table

498 Elements of the Interactive Graphics Window Once you have selected the file or files to view, they are displayed in the Interactive Graphics w

Página 448

499 You can size and position the Locator Window anywhere on the screen. The Locator Window can be closed by clicking on the button in the upper r

Página 449 - Calibration Setup

500 A separate attenuation control appears for each chromatogram. When you right click on a chromatogram trace, either in overlay or tiled mode,

Página 450

501 The Attenuation Control Located on the right side of the chromatogram display is an attenuation control, similar to a scrollbar which allows y

Página 451 - Coefficients Table

502 Toggle display of the Locator Window, the Method Quick Link button, the main Toolbar, or the Status Bar (at the bottom of the window). Toggle

Página 452 - Calibration Curve Window

503 These settings affect what additional information is displayed with the chromatogram. See the explanation of this option below. These settin

Página 453 - This Report Only Dialog Box

504 You may specify the colors for each of the seven possible chromatogram traces that can be displayed simultaneously in Interactive Graphics. Yo

Página 454 - Overlay Window

505 If you wish to use Data Handling parameters from a Method file already stored on disk but not automatically opened when you selected the chrom

Página 455 - Coefficients Dialog Box

506 Select the method section you wish to open. If you wish to open the Method originally used with any chromatogram that is currently opened in I

Página 456 - Verification Setup

507 When you select Build Method from Data File, you are prompted for the name of the Method file to be created. This new Method then becomes the

Página 457 - Time Events Table

49 Item Description Manual Control Click the Manual Control to turn on or off the trap controls (rf, Filament, and Multiplier) and to open the CI

Página 458 - Time Events

508 Peak Table The Peak Table is used to identify peaks so that results may be calculated. Refer to the on-line help in Interactive Graphics for d

Página 459 - Event Description

509 This field describes acceptable values for the Value / End Time cell. Calibration Setup Calibration Setup parameters determine the type of ca

Página 460

510 Edit calibration coefficients. Locked coefficients are not updated by calibration runs. Verification Setup Verification Setup options affect t

Página 461

511 When you check this, peaks detected in any region that you select in the Chromatogram Display Window are automatically added to the peak table

Página 462

512 To add a new time event, right-click in the Interactive Time Events window at the time where you wish the event to occur. When you right-cli

Página 463 - Run Information

513 Moving Peak Start and End Points Peak start and end points are indicated on the chromatogram as lines or triangles (depending on the options s

Página 464 - Open Method File Dialog Box

514 The Reintegration List is displayed. Set the run type (analysis, calibration, verification, baseline). If you are calculating results using a

Página 465

515 Viewing Results You may view results for each peak by enabling the Cursor/Peak Information display from the Chromatogram Display Toolbar. Cl

Página 466 - Save Method As Dialog Box

516 Viewing Calibration Curves If you are performing calibrated calculations (external standard, internal standard or normalized percent), you may

Página 467 - Preferences Dialog Box

517 Double-click on a calibration point to see more information. Select the peak whose curve you wish to view. Changes made here only affect the s

Página 468 - Layout Tab

50 Instrument Settings Item Description Method button Opens the Method Editor program. Segment # box Select the current segment of the active

Página 470

519 GC Standard Report Method Command Reference Print Options

Página 471 - Offsets Tab

520 Single Run Reports: Item Description Title Up to 60 characters Assigns a title to the report. Print Chromatogram When checked, the Workstat

Página 472 - Colors Tab

521 Results Format Item Description Units Any units, up to 10 characters Assigns a name for the units used in the results report. Number of De

Página 473

522 Chromatogram Format Item Description Start Retention Time, mins 0.00 to 1440.00 Specifies a start time after injection for the chromatogram

Página 474

523 Item Description Length in Pages 0 to 9 Sets the number of pages used to print a chromatogram. This option takes precedence over the chart spe

Página 475 - Fill Peak Table Window

524 Item Description Chart Speed 0 .1 to 30.0 Sets the program chart speed. Attenuation 1 to 4096 Sets the program attenuation.. Attenuation is

Página 476 - Exact View Dialog Box

525 Generating GC Standard Reports The Standard GC Reports Method Section Note that information about using other reporting applications such as t

Página 477 - File Menu

526 Creates an ASCII file containing the results report. The file is named based on the Data File name and channel label, with the extension “.txt

Página 478 - View Menu

527 Fits the high and low amplitudes to the page. Peaks inhibited with II or SR time events are ignored. When not using Auto Scale, you can time

Página 479 - Results Menu

51 Item Description Adjust Cal Gas Click to adjust the cal gas pressure. Adjust rf Ramp Change the rf setting for the instrument by turning the

Página 480 - Edit Method Menu

528 Amount units label the X axis of the curve. Refer to the on-line help in Report for details on all fields in the Report Method section. Autom

Página 481

529 Automated Printing to Multiple Printers If you are running automation on more than one instrument, you may wish to designate a separate printe

Página 482

530 Batch Report Printing without Recalculating When you perform batch recalculations in System Control, reports are automatically generated using

Página 483 - Toolbar Overview

531 Batch Printing with Batch Report You may print reports for a set of Data Files without using System Control. Click on the GC Batch Reporting

Página 484 - Chromatogram Toolbar

532 Click on the Standard GC Reports icon in the MS Workstation Toolbar. The Open Data File dialog box is displayed. Select the Data File. Sele

Página 485

533 Specify report formatting parameters. The Data File and Method Quick Link buttons provide access to additional operations, such as reintegrati

Página 487 - Locator Window

535 Method Builder Dialog Boxes Create/Open Method File Dialog Box Item Description Select a method file action If Create a New Method File is

Página 488 - Main Window

536 Open Method File Dialog Box Item Description Look in Lists the available folders and files. To see how the current folder fits in the hier

Página 489 - Zooming and Scrolling

537 Item Description Notes When checked, displays any notes and/or revision log associated with the currently selected file. Open Opens the sel

Página 490 - Moving Baselines

52 Item Description Start Auto Tune Begins the event sequence that will tune the instrument. Only checked boxes will be executed. Reset Stops th

Página 491 - Info-Panels

538 Item Description File name Shows the currently specified file. Save as type Specifies the type of file to save. Recent Files Click on this

Página 492 - Run File Info-Panel

539 Change Password Dialog Box Item Description Enter Current Password Enter the password currently used to protect the Method. Enter New Pass

Página 493 - Visual Method Edit Window

540 Print Method Sections Dialog Box Item Description Sections to Print Lists the sections of the Method. Selected sections will be printed. To

Página 494 - Types of Time Events

541 Star Printer Setup Dialog Box This dialog box is used to specify the printers that will be used by Varian MS Workstation applications both int

Página 495

542 Delete Method Sections Dialog Box Item Description Sections to Delete Lists the sections of the Method. Selected sections will be deleted.

Página 496 - Right Mouse Menus

543 Import Method File Sections Dialog Box Item Description Sections to Import Lists the sections of the Method. Selected sections will be imp

Página 497 - Action Effect of Action

544 Select Configuration Item Description Select a Configuration Select Custom in order to add any configuration of hardware modules to the Met

Página 498

545 Configure Modules Item Description Available Modules Lists the hardware modules that can be configured in the Method file. Configured Modul

Página 499 - GC Interactive Graphics

546 Item Description Cancel Closes the Star Assistant. Nothing is added to the Method file. Select Detectors for Post-Run Processing Item Descr

Página 500 - The Locator Window

547 Create Sections for Post-Run Processing Item Description For the following module Specifies the detector module and address for which post-

Página 501

53 Item Description Electron Multiplier Voltage Manual adjustment of the Final Gain Setting determine from the Auto Tune check. SIS Amplitude Ad

Página 502

548 Confirm Configuration Item Description Added Configuration Displays the hardware modules, hardware control methods, and any post-run proces

Página 503 - Changing Viewing Options

549 Method Builder Menus File Menu Menu Item Description New Starts the Star Assistant Method Configuration dialog to aid and guide you through

Página 504 - The Preferences Dialog Box

550 Menu Item Description Exit Closes Method Builder. If you have made any changes to the Method, you are prompted to save the changes before cl

Página 505 - Offsets

551 Menu Item Description Tile Vertically Tiles the open Method Windows vertically (side by side). Tile Horizontally Tiles the open Method Wind

Página 507

553 Method Builder Toolbars Overview There are three toolbars on the main window: the Main Toolbar, the Directory Toolbar, and the Window Toolbar.

Página 508

554 Copies selected items to the clipboard. Pastes the clipboard contents to the selected item. Deletes selected items. If a Method section is

Página 509 - Integration Parameters

555 Window Toolbar When pressed, the RecalcList Generation Dialog Box pane is displayed. This pane provides a tree-structured view of the Metho

Página 511

557 Method Builder Window Overview The Method is displayed in a window that is split into a left and a right pane. The left pane is the Method Di

Página 512 - Filling the Peak Table

54 Item Description Start Click Start to execute the desired test Reset Cancel a test executed with Start. System Test Item Description Run T

Página 513

558 window from the Window menu. In addition, if you open another Method file from the File menu of Method Builder, the Method file is displayed i

Página 514 - These events are selected

559 module is expanded into the groups of editable parameters for the control method of that module. If a minus (-) sign is displayed to the left

Página 516

561 Module Information Editor Module Information Editor Information about the hardware modules composing your instrument(s) can be maintained and

Página 517 - Viewing Results

562 Entry Description PO# = 123456 Item1 = value1 SO# = A12345B Item2 = value2 Current Limitations There is no protection against duplicated se

Página 518 - Viewing Calibration Curves

563 Adding an Entry to a Section 1. Using the mouse or the arrow keys, select the line within the section where you want to insert a new entry.

Página 519

564 Creating a Default Module Information Template New .MDF files can be created based on a template file. If MODULE00.MDF is found in the Workst

Página 520

565 When you replace a hardware component, zero out (or adequately edit) the associated number of injections. You can also save free-form text by

Página 521 - GC Standard Report Method

566 confirm this deletion before it is done. File Menu The File menu contains the following commands: Item Description Save Save the contents of

Página 522

567 When renaming an existing section, the name field is initialized with its current value. Type in the new name for the section. Press OK if you

Página 523 - Results Format

55 Monitor Window Item Description Multiplier check box Display the voltage (center left) on the multiplier when on. rf check box For Service

Página 525

569 Security Administration Overview The Security Administration window contains three window tabs that can be used to select the categories of se

Página 526

570 Item Description Password for this application Allows you to specify a password required to enter the Security Administration application. No

Página 527 - Print Options

571 Application Locking Item Description Unlocked Applications This list box shows all top level windows currently running and are not locked.

Página 528

572 File Revision Settings Item Description Require Revision Log entry when changes to Methods are saved. When checked, the user is prompted for

Página 529

573 Item Description Disable creation of new passwords in Method files. When checked, new passwords cannot be added to Methods. Methods already co

Página 531 - Select Printer Setup

575 Standard GC Reports Command Reference File Menu Menu Item Description Open Displays the Open Data File dialog box. Print Displays the Prin

Página 532 - Specify a Print action

576 View Menu This menu is displayed when the chromatogram window is active. Menu Item Description Change Plot Color Displays a dialog box allow

Página 533

577 Help Menu Menu Item Description Help Topics Displays the help you are now viewing. Product Support Web Site If you have Internet access and

Página 534 - Select the Data File

56 Shutdown Mode Item Description Shutdown button Shuts down the system in an orderly manner. The pump speed is slowly reduced and the heaters ar

Página 536

579 Standard GC Reports Dialog Boxes Open Data File Dialog Box Item Description Look in Lists the available folders and files. To see how the cu

Página 537 - Method Builder Dialog Boxes

580 Item Description Run Information Shows information about the currently selected file, including a thumbnail view of the chromatogram. If you a

Página 538

581 Printer Setup Dialog Box Item Description Default Saturn Printer Displays the printer that is used when printing interactively from Varian M

Página 539

582 Chromatogram Options Dialog Box Item Description Start Retention Time, mins 0.00 to 1440.00 Specifies a start time after injection for the

Página 540 - Add Password Dialog Box

583 Item Description Initial Chart Speed, cm/min 0.0 to 30.0 Sets the initial chart speed for the printout. This speed does not change unless you

Página 541 - Change Password Dialog Box

584 Item Description Attenuation 1 to 4096 Sets the program attenuation.. Attenuation is relative to the maximum full scale value of the detector

Página 542

585 Notes Includes the notes you entered when you made the injection (original notes) and when you recalculated (appended notes) as part of the

Página 544

587 Standard GC Reports Format Descriptions Results Report Below is an example of a results report generated from an analysis run. The exact forma

Página 545 - Star Assistant Wizard

57 Turn OFF main power by placing switch at rear of system into OFF (down) position. Manually vent the system for at least 5 minutes using the lev

Página 546 - Select Configuration

588 Title : Title Run File : Data File name Method File : Method File name Sample ID : Sample name Injection Date: Date/Time

Página 547 - Configure Modules

589 [Module Run Logs] Time Events: [Data Handling Time Events] Error Log: [Module Error Logs] Calibration Report: [Calibration Report Text] Revis

Página 548

590 Item Description Measurement Method section. Either Area, Height or Square Root of Height. Calculation Type Set in the Integration Parameters

Página 549

591 Item Description Group This column is shown when the Show Peak Group Totals checkbox is checked in the Results Format portion of the Report M

Página 550 - Confirm Configuration

592 Item Description The noise used by Data Handling depends upon the noise options set in the Integration Parameters Window in the Data Handling

Página 551 - Method Builder Menus

593 Verification Report Below is an example of a results report generated from a verification run. The exact format of your verification reports m

Página 552 - Window Menu

594 9 Peak 5.580 1.0000 1.4435 44.3 5.586 -0.001 297265 --- ------------ ---------- ========== ----- ------- ======= ==

Página 553

595 Standard GC Reports Toolbar Main Toolbar Displays the Open Data File dialog box. Displays the Print dialog box. Converts the text results

Página 554

4 Tandem Mass Spectrometry (MS/MS)...

Página 556 - Directory Toolbar

59 2000 MS Instrument Window The 2000 MS Instrument Window System Control has four major sections: the System Control Menu bar, System Control T

Página 557 - Window Toolbar

60 Activate Method allows you to choose a method from those already prepared. This will set the conditions for the GC, MS, AutoSampler and data ha

Página 558

61 Edit Menu Click the Edit menu and highlight Edit Module Info. Each module in your system (3800GC, 2000MS, 8200 AutoSampler) contains its ow

Página 559 - Method Builder Window

62 Inject Single Sample Menu The command will allow you to give the sample information prior to an injection. The dialog box below will appear w

Página 560 - Method Directory

63 Automation Menu Below is a picture of the Automation pull down menu and a description of the functions. Begin Sample List will cause an automa

Página 561 - Method Parameters

64 Begin RecalcList will allow you to start an automated recalculation. A recalculation list must already be prepared and selected to do this. A N

Página 562

65 Instrument 1 Faults allows you to see if there are any faults in any of the modules contained in Instrument 1. An example of this screen is sho

Página 563 - Module Information Editor

66 Instrument 1 Status allow you to view the status of the modules connected to the system. Message Log allows you to view the event log for the M

Página 564 - Renaming a Section

67 In the Help dialog box, from the Index tab, you can select a particular topic. Click the selection, go to the bottom of the screen and click D

Página 565 - Adding an Entry to a Section

5 3800 GC System Control Command Reference...303 Status and Control Window...

Página 566

68 System Control Toolbar The system control toolbar is located near the top of your screen. A picture of this toolbar is displayed below. Clic

Página 567 - Commands

69 Clicking on this button allows you to start a sample list that you have created. The list must already be selected. Clicking on this button

Página 568 - Dialog Boxes

70 Spectrum Toolbar Click the arrow to hide the toolbar. Click the upper left of the screen to restore the toolbar. Click full scale to nor

Página 569

71 Choosing the Chromatogram only option will allow you to see a live chromatogram as in the example below. Click Hide Keypad to expand the chrom

Página 570

72 Choosing the Spectrum only will allow you to see a live spectrum as in the example below. Click hide keypad to expanded the display.

Página 571 - Security Administration

73 Click Show Keypad to display the keypad. Status and Control Window You are now ready to program the GC/MS to perform fully automated data acqu

Página 572

74 You must select a method segment that is not a Filament/multiplier delay segment for the ion trap to be enabled. This method and segment select

Página 573 - Application Locking

75 The informational fields displayed in the above dialog are taken from the currently executing method. The Scan Mode describes the ionization m

Página 574 - File Revision Settings

76 Two filaments are provided to reduce down time for maintenance. The selection of the filament is made by choosing the radio button. The Axial

Página 575

77 When the rf Modulator Response screen is displayed, it shows a real time view of the rf modulator response from 20 to 650 m/z. The vertical ax

Página 576

6 Sequence Window...

Página 577 - Standard GC Reports Command

78 When it is properly adjusted, the dialog will say the rf response is within limits. When you are finished, select the Done button. To adjust th

Página 578 - Options Menu

79 In CI, as in EI, the Saturn GC/MS is tuned to achieve the best combination of maximum peak height (sensitivity), optimum resolution of peaks,

Página 579

80 Increase the CI gas pressure by adjusting the CI needle valve on the front of the 2000. Turn the knob clockwise to increase the pressure. When

Página 580

81 Control and Status The Auto Tune methods are started from this display by clicking on the Start Auto Tune button. The method maybe stopped by

Página 581

82 An example: The dialog for the air/water check is shown below. The mass 28 peak width is used to determine if air is present in the trap. The

Página 582 - Print Dialog Box

83 Auto Tune Checks In the top center of the screen you will see 4 check boxes. These are the auto tune steps that are to be performed. If your s

Página 583 - Title Dialog Box

84 On the left side of the dialog box is an progress bar that indicates the relative amount of AIR in the system. A message is displayed below th

Página 584

85 The Electron Multiplier Tune will determine three proper settings: the Integrator Zero, the 105 gain for the Electron Multiplier and the Elec

Página 585

86 sensitivity and resolution. This setting is also the value displayed in the Set Points dialog, in the Electron Multiplier voltage field. Mass C

Página 586 - Results Options Dialog Box

87 is outside of these limits, check if the rf voltage amplitude is adjusted properly over the entire mass range). Straight Line Mass Calibration

Página 587 - Find Dialog Box

7 Save Method As Dialog Box...

Página 588

88 SIS Amplitude Adjust Factor. Each trap system must be adjusted for optimum ion sensitivity and ejection. See Tutorial on SIS Calibration for yo

Página 589 - Descriptions

89 Whenever you execute changes, the event log at the bottom of the screen will be updated with the time and the event that has occurred. The scr

Página 590

90 The Monitor and Event Message window will detail results of the basic system. If a fault had occurred, the message would indicate what test fa

Página 591

91 Also, present temperature values for each of the heating zones is displayed. Monitoring diagnostics on startup will identify any problems.

Página 592

92 action will cause the heaters to be turned off and the system will begin to cool. Additionally, the turbo pump will be slowly turned off. In th

Página 593

93 the cooler has warmed to the point that it won’t condense water vapor, and the pump is considered to be off. The DIFFUSION PUMP STATUS then cha

Página 594

94 NOTE: The Vacuum System status should be periodically checked during Startup for foreline pressure. The pressure should read below 500 mTorr

Página 595 - Verification Report

95 In the above screen there are additional buttons which allow you to browse or check data files that already exist to make sure that you are not

Página 596

96 Select one of the 3 radio buttons and name the recalculation list you are using if appropriate. In order to perform automated injections of a g

Página 597 - Standard GC Reports Toolbar

97 scanned out of the ion trap. Thus, when the multiplier gain is changed, there is no change in the actual quantity of ions formed and measured i

Comentários a estes Manuais

Sem comentários