Item Description
Col Oven Setpoint Abient+5 °C to 450 °C
Displays the column oven
programmed temperature setting in
the active method.
Col Oven Actual Abient+5 °C to 450 °C
Displays the actual temperature of the
column oven at the 3900 GC
1177 Setpoint 50 to 450 °C
Displays the 1177 injector oven
programmed temperature setting in
the active method.
1177 Actual 50 to 450 °C
Displays the actual temperature of the
1177 injector oven at the 3800 GC.
Oven Status Display
Oven Parameters:
Item Description
Column Ready Yes or No.
The column oven is Ready (Yes) if the setpoints have
been achieved and stabilized. The column oven is Not
Ready (No) if readiness to start a run has not been
achieved or if, during a run, the oven becomes not ready
or goes “out of tolerance”. Some reasons the GC may go
Not Ready during a run are: the temperature program is
too aggressive, the oven door is opened, the coolant
runs out, the power line voltage drops, etc.
Column Fault Yes or No.
Displays if a fault in the column oven component has
occurred.
Injector Ready Yes or No.
The injector oven is Ready (Yes) if the setpoints have
been achieved and stabilized. The injector oven is Not
Ready (No) if readiness to start a run has not been
achieved or if, during a run, the injector becomes not
ready or goes “out of tolerance”. .
Injector Fault Yes or No.
Displays if a fault in the injector oven component has
occurred.